Rotary R.E.B. Union (Sizes 1-1/2" to 6")
Maintenance and Overhaul
• Remove nuts (13) and washers which allows for the removal of adaptor (4). • Remove bellows subassembly and gasket of seal kit (5). • Remove locking screw (7) and unscrew locking ring (14 - RH Thread) and extract spindle (15) complete with ball bearings, etc. • Remove locking screws from the rubbing ring of seal kit (5), unscrew the rubbing ring (RH or LH thread) and remove gasket. • Thoroughly clean the ball bearing kit (11), check the condition of the bearings and re-grease. If there is any doubt about the condition, replace the bearing kit and pre-pack with an approved grease. • To replace the bearing kit (11), remove locking screws (8), bearing locking ring (9 - RH or LH Thread) and Nilos ring (10). Press off the bearing kit. • If the adaptor (4) is Type R.S., remove locking screw (3), unscrew locking ring (1 - RH Thread) and remove C/T bearing (2).
• Replace seal kit (5),
bearing kit (11) and if type RS, C/T bearing (2). Handle seal kits with
care to avoid damaging the precision lapped seal faces. • After reassembly, follow the recommended installation procedures and allow for a suitable run-in period to ensure the seals are working correctly before refitting to the machine.
* Note:
For the 125 (5”) and 150 (6”)
models, there is a screwed
|
|
||||||
|
|
|
|
|
||||
|
|
|||||||